Generator Neutral Grounding Resistor Cabinet

Generator Neutral Grounding Resistor Cabinet

The Generator Neutral Grounding Resistor Cabinet is the core equipment of the neutral - point grounding protection system for large generator sets. By connecting a precisely calculated resistor in series between the generator neutral point and the ground, it limits the fault current in the event of a single - phase grounding fault in the generator stator winding to a safe and controllable range. This critical protection device ensures generator safety, prevents severe core burnout, and ensures reliable operation of the relay protection system.
Send Inquiry

Product Introduction

 

The Generator Neutral Grounding Resistor Cabinet is the core equipment of the neutral - point grounding protection system for large generator sets. By connecting a precisely calculated resistor in series between the generator neutral point and the ground, it limits the fault current in the event of a single - phase grounding fault in the generator stator winding to a safe and controllable range. This critical protection device ensures generator safety, prevents severe core burnout, and ensures reliable operation of the relay protection system.

 

Product Picture

 
image002
image004

 

Triple Protection Mechanism

 

 

Current Limiting: Controls single - phase ground fault current to 5% - 20% of the generator's rated current, preventing arc damage to the stator windings.

Voltage Suppression: Limits transient overvoltage to 2.6 times the phase voltage to prevent magnetic saturation of the core.

Fault Isolation: Combined with the zero - sequence protection device, locates the fault phase within 0.5 seconds, preventing overvoltage in non - fault phases.

 

production equipment

 

 

image004

image006

 

Device Features

 

Highly Targeted, Precise Protection

The generator neutral grounding resistor cabinet is suitable for low - resistance and medium - resistance grounding systems. In the event of a single - phase grounding fault, it limits overvoltage to no more than 2.6 times the phase voltage through additional resistive current, ensuring rapid disconnection of the fault line and preventing equipment damage.

Compact Structure and Easy Installation

This cabinet integrates a Z - type grounding transformer (optional), resistors, instrument transformers, and instruments within a sealed metal cabinet. An optional disconnect switch is available. Supplied as a complete set, the cabinet offers a clear layout and facilitates commissioning and maintenance.

High - Quality Materials and Reliable Performance

Transformer: Dry - type Z - type wiring with strong insulation performance.

Resistors: Nickel - chromium/stainless steel alloy, high - temperature resistant (1600°C), stable resistance (with an extremely low temperature coefficient magnitude of ≤ 0.045%/°C), and flameproof and explosion - proof.

Overall: Corrosion - resistant and impact - resistant, with a service life exceeding 20 years.

 

About the factory

 

 

image017-1

product-1000-563

 

FAQ

 

 

Q: Can it be used in high-altitude/coastal environments?

A: Yes: It's dust-proof in high-altitude environments and salt-spray-proof at the coast, having passed extreme environment testing.

Q: Is installation difficult? Do you provide commissioning?

A: Installation is easy: It can be completed within one day, and we provide video instructions and 24-hour phone support.

Q: What information should I provide when purchasing?

A: Main requirements include: generator model, rated voltage, desired grounding current, and whether it's for indoor/outdoor use.

Hot Tags: generator neutral grounding resistor cabinet, China generator neutral grounding resistor cabinet manufacturers, suppliers, factory, Alloy Neutral Grounding Resistor, Distribution Network Grounding Resistor Cabinet, Generator Neutral Grounding Resistor Cabinet, neutral grounding resistor, Neutral Grounding Resistor Cabinet, Transformer Neutral Grounding Resistor